Searching for reliable protection against overcurrent and electrical faults? A 250 AMP MCCB (Molded Case Circuit Breaker) provides robust protection for industrial and commercial electrical networks, safeguarding against overcurrent and fault conditions while ensuring reliable and efficient power distribution. At Eleczo, you’ll find a wide selection of 250 AMP breakers from trusted brands such as Schneider Electric, Siemens, Lauritz Knudsen (L&T), ABB, C&S Electric, Hager, Indoasian, and Legrand, all built to deliver exceptional quality, durability, and helping you ensure safe and reliable power distribution for your electrical products.
250 AMP MCCB (Molded Case Circuit Breaker) is commonly used to control current flow and minimize risk in industrial and commercial electrical networks. These breakers are designed to handle high currents, prevent damage from fault conditions, and ensure uninterrupted power distribution for critical operations.
|
|
|
|
|
These MCCBs are ideal for products that demand reliable, high-performance protection, helping businesses maintain safety, and prevent downtime.
When selecting a 250 AMP MCCB, you should consider key technical factors to ensure it meets your product’s requirements. This helps prevent downtime, avoid equipment damage, and maintain long-term reliability.
|
|
|
|
Eleczo India Private Limited, formerly known as Mohan Exim India Pvt. Ltd., brings over 57 years of experience in the electrical industry and has earned a reputation as a trusted source for electrical components in India. Our platform offers a wide selection of 250A MCCBs from verified premium brands, ensuring high-quality standards, certified safety, and reliable performance. Each breaker is engineered to provide robust circuit protection, long-lasting durability, and efficient power distribution, giving buyers confidence in every installation.
With fast Pan-India delivery, flexible payment options, and authentic products, Eleczo makes it simple to procure MCCBs for single projects or large-scale electrical products. Trust Eleczo for your industrial and commercial electrical protection needs, combining quality, reliability, and convenience in every order.
|
|
||||||||||||||||||||||||||||
250 Amp MCCB Price List in India 2025-2026 |
||
|---|---|---|
| Product List | Selling Price | |
| Siemens 3VM12254GE420AA0 MCCB 3VM 250 A, 4 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.26,351.10 | |
| Schneider Electric LV525303 MCCB EasyPact CVS 250 A, 3 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.12,391.20 | |
| Schneider Electric LV525313 MCCB EasyPact CVS 250 A, 4 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.15,159.60 | |
| Legrand 4202 09 MCCB DPX3 250 A, 3 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.16,045.80 | |
| Legrand 4202 49 MCCB DPX3 250 A, 4 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.23,622.20 | |
Siemens 250 Amp MCCB Price List in India 2025-2026 |
||
|---|---|---|
| Product List | Selling Price | |
| Siemens 3VJ1225-3DA32-0AA0 MCCB 3VJ 250 A, 3 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.6,759.00 | |
| Siemens 3VJ1225-3DB32-0AA0 MCCB 3VJ 250 A, 3 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.8,103.60 | |
| Siemens 3VJ1225-7EA42-0AA0 MCCB 3VJ 250 A, 4 Pole, 55 kA, Thermal Magnetic Trip Unit | Rs.14,308.20 | |
| Siemens 3VA1225-4GF42-0AA0 MCCB 3VA 250 A, 4 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.32,651.50 | |
Lauritz Knudsen (Formerly L&T Switchgear) 250 Amp MCCB Price List in India 2025-2026 |
||
|---|---|---|
| Product List | Selling Price | |
| Lauritz Knudsen (L&T) CM90638OOPO MCCB d sine DN 250 A, 3 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.14,382.00 | |
| Lauritz Knudsen (L&T) CM90642OOPO MCCB d sine DN 250 A, 4 Pole, 25 kA, Thermal Magnetic Trip Unit | Rs.16,677.00 | |
| Lauritz Knudsen (L&T) CM98060OOOO MCCB DU 250 A, 3 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.9,734.00 | |
| Lauritz Knudsen (L&T) CM92009OOP1OG MCCB d sine DN 250 A, 3 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.16,219.00 | |
| Lauritz Knudsen (L&T) CM92054OOOOX1 MCCB d sine DN 250 A, 3 Pole, 36 kA, Microprocessor Trip Unit | Rs.24,794.00 | |
Schneider Electric 250 Amp MCCB Price List in India 2025-2026 |
||
|---|---|---|
| Product List | Selling Price | |
| Schneider Electric LV525333FT MCCB 250 A, 3 Pole, 36 kA, Thermal Magnetic Trip Unit | Rs.31,500.00 | |
| Schneider Electric LV525505 MCCB EasyPact CVS 250 A, 3 Pole, 25 kA, Microprocessor Trip Unit | Rs.51,960.00 | |
| Schneider Electric LV525508 MCCB EasyPact CVS 250 A, 4 Pole, 25 kA, Microprocessor Trip Unit | Rs.66,640.00 | |
| Schneider Electric LV525610 MCCB EasyPact CVS 250 A, 4 Pole, 25 kA, Microprocessor Trip Unit | Rs.86,170.00 | |
| Schneider Electric LV525509 MCCB EasyPact CVS 250 A, 4 Pole, 36 kA, Microprocessor Trip Unit | Rs.27,136.80 | |
An MCB (Miniature Circuit Breaker) is typically used for low and medium current applications with compact ratings, whereas an MCCB (Molded Case Circuit Breaker) at 250A is designed for higher current industrial and commercial loads with higher breaking capacity and adjustable trip settings.
Yes, a 250A MCB can be used as the main incoming or sub main breaker in a distribution board, provided its voltage, pole configuration, and breaking capacity match your product requirements and local electrical codes.
Add up the total current (in amps) of all connected equipment, then choose a breaker rating slightly higher than this value (e.g., for a 200A load, a 250A MCB is appropriate) to avoid nuisance tripping while still providing protection.
The trip curve (B, C, D) defines how sensitive the breaker is to short circuit surges. B curve is for resistive loads, C curve for general commercial loads, and D curve for high inrush equipment like motors and transformers.
The breaking capacity (Icu) is the maximum fault current the 250A MCB can safely interrupt without damage. Typical values range from around 10kA to 50kA or higher, depending on the model and application.
Yes, a 250A MCB is commonly used for industrial motor protection and heavy load circuits, especially when paired with the correct trip curve and adequate breaking capacity for the motor’s starting inrush.
Frequent tripping can be due to overload, short circuit, loose wiring, a mismatched trip curve, or a faulty breaker. If the problem persists, an electrician should check the load, wiring, and MCB condition.
A 250A MCB is usually used for main or sub mains rather than individual house circuits. For standard home wiring, smaller breakers (e.g., 16A, 20A, 32A) are used, while the 250A unit may serve common areas or high power equipment.
A quality 250A MCB can last many years if installed correctly, operated within its rated capacity, and regularly maintained. Avoid repeated frequent tripping and extreme environments to maximize lifespan.
Most 250A MCBs conform to international standards such as IEC 60947-2 (low voltage circuit breakers) and relevant national standards (e.g., IS codes in India), ensuring tested performance and safety.
A 250A MCB protects against overcurrent and short circuit faults, but it does not regulate voltage. For voltage issues, use a separate voltage stabilizer or surge protector alongside the breaker.
Sitemap Visit Mohan Exim
ELECZO INDIA PRIVATE LIMITED © 2016 - 2026 ELECZO.com. All Rights Reserved.